Function:
temperature measurement of airflow in air-pipe of the energy unit
Application:
applied at sites with atomic power plants
Specifications
| Detector type | Thermal couple |
| Temperature measurement range, oС | From 0 to 200 |
| Measurement range, humidity, % | From 0 to 100 |
| Working temperature range, оС | From 0 to +50 (for IRT-5922A) |
| Protection level | IP53 |
| Input current, VA | 50 |
| Time to failure, h | 40000 |
| Equipment |
|
| Dimensions, mm IPTV-056A IRT-5922A |
300х60х25 260х120х250 |
| Weight, kg IPTV-056A IRT-5922A |
2 4,5 |
| Output type | Current over two channels |